To submit total RNA for cRNA synthesis and gene expression analysis, the following must be provided:
To submit fragmented cRNA for gene expression analysis, the following must be provided:
For quantification of cRNA when using total RNA as starting material, an adjusted cRNA yield must be calculated to reflect carryover of unlabeled total RNA. Using an estimate of 100% carryover, use the formula below to determine adjusted cRNA yield: adjusted cRNA yield = RNAm -(totalRNAi )(y) Example: Starting with 10 µg total RNA, 50% of the cDNA reaction is added to the IVT, giving a yield of 50 µg cRNA. Therefore, adjusted cRNA yield = 50 µg cRNA - (10 µg total RNA)x(0.5 cDNA reaction) = 45.0 µg. An outline of the protocol is shown to the right.